Xantrex

Xantrex (14)

AMP-IT-UP! NEW 24-Volt Universal Chargers

Publicado em: Xantrex ,
Escrito por Quarta, 06 Setembro 2017 14:27

AMP-IT-UP! NEW 24-Volt Universal Chargers

Building on the success of the TRUECharge™2 12-volt battery chargers, Xantrex™ now offers 24-volt battery chargers designed to meet the specific needs of marine and commercial markets. Available in 10A, 20A and 30A versions, each model packs a powerful universal charger (90-240Vac, 47-63 Hz) in an ultra-compact, lightweight package.

TRUECharge2 battery chargers are highly versatile and can be mounted in multiple positions, thanks to their inherent drip-free design characteristics. TRUECharge2 delivers outstanding low electrical interference, coupled with efficient, power factor corrected, multistage charging capability. Installation is a breeze, thanks to the easy-access AC and DC wiring compartments. The easy-to-read display can be
augmented with an optional remote panel.

 

NEW PARALLEL FEATURE

TRUECharge2 24-volt chargers are available with parallel stacking feature which allows you to double the output current when used with the optional REMOTE PANEL (part #808-8040-01).

 

 

 

 

Performance Features:

  Microprocessor-controlled, multistage charging algorithms

  Settings for two and three-stage charging

  Settings for flooded, gel, AGM or lead-calcium batteries

  Auto-ranging universal input voltage (90-265 Vac, 47-63 Hz) is also compatible with a generator or other low-quality power sources

  Power factor corrected, temperature-compensated charging

  Battery-equalization feature

  Ability to charge batteries drained to extremely low voltage

  Optional Battery temperature sensor (Part #808-0232-01)

  Optional Remote Panel (Part #808-8040-01)

 

Protection Features:

  Reverse battery polarity protection

  Drip-proof design

  Over and under-temperature protection

  DC over-voltage protection

  Battery overcharging protection

 

Also available in 12-volt models: 10 A, 20 A, 40 A and 60 A.

10 A, 20 A and 30 A 24-volt Multistage Battery Chargers  

Electrical Specifications (@ 25°C unless otherwise noted)  

Models

TRUECHARGE2 10 / 20 / 30

Output current (nominal)

10 A / 20 A / 30 A

Output voltage (nominal, depending on battery type settings)

Charge

28.4 - 31.0 Vdc

Float

26.8 - 27.6 Vdc

Equalize

32 Vdc

DC output connections

Three
AC input voltage 1 90-265 Vac 47-63 Hz

120 Vac, 230 Vac, 240 Vac nominal
Temperature compensation Three settings
Charger efficiency > 80%
Battery type Gel, Flooded, AGM and Pb-Ca
Minimum recommended battery bank size 40 Ah / 80 Ah / 120 Ah

 

 

General Specifications  

Models

TRUECHARGE2 10 / 20 / 30

Operating temperature 2

0 to 60°C

Storage temperature

-40 to 80°C

Battery connection

Three positive terminals

One negative terminal

Dimensions (H x W x L)

10 A & 20 A - 2.8 x 6.7 x 9.8” (70 x 170 x 250mm

30 A - 3.5 x 6.7 x 13.4” (90 x 170 x 340 mm)

Weight

10 A & 20 A - 4.8 lb (2.2 kg)

30 A - 9.9 lb (4.5 kg)

Warranty

Two year

Part Numbers

804-2410 / 804-2420 / 804-2430

 

Accessories  

Remote panel

808-8040-01

Battery temperature sensor

808-8040-01

     

Regulatory Compliance

CSA E60335-2-29, UL1564, and UL1236 including the Marine Supplement, drip test, and Ignition Protection ratings. CE Marked for the Low Voltage Directive
(safety) and the EMC Directive. Complies with IEC 60335-2-29 including Australian deviations. Ingress protection rating IP32 per EN/IEC 60529. Complies with
FCC Part 15B and Industry Canada ICES-003 Class B emissions limits. Complies with ABYC A-31

     

1 90 - 104 Vac ± 4 Vac output de-rated to 80% of full load current
² For all three models, the output current may derate above 50°C.
Highly Accelerated Life Tested (HALT) to -20°C.
Note: Specifications subject to change without notice.

 

Three-Stage Charging

Multistage charging helps ensure batteries receive optimum charging, but with minimal wear and tear, regulating the voltage and current delivered
to the batteries in three automatic stages:

 

  Bulk: Replaces 70-80% of the battery’s state-of-charge at the fastest possible rate.

  Absorption: Replenishes the remaining 20-30% of charge, bringing the battery to a full charge at a slow, safe rate.

  Float: Voltage is reduced and held constant in order to prevent damage and maintain batteries at a full charge.

 

Power Factor Corrected (PFC)

Less shorepower is required for charging batteries, freeing up more usable AC power for running electrical devices and appliances and reducing.

 

 

 

Copyright © 2011 Xantrex Technology Inc. All rights reserved. Xantrex, TRUECharge and Smart choice for power are trademarks of Schneider Electric Services International sprl, registered in the United States and other countries.

TRUECHARGE TM2 Battery Chargers – 12-volt

Publicado em: Xantrex ,
Escrito por Terça, 05 Setembro 2017 20:47

Redesigned, High Performance, Worldwide Charging

XantrexTM TRUECHARGE TM2 Battery Chargers lead the industry with a small footprint and ultra-compact design. In addition to meeting global safety and regulatory standards, TRUECHARGE2 Battery Chargers feature low electrical interference and efficient, power factor corrected multistage charging. TRUECHARGE2 Battery Chargers can be mounted virtually anywhere, given their unique drip-proof design. With certified ignition protection, even a gasoline engine room is an alternative for installation*. Trouble-free installation is ensured with easy-to-access AC and DC wiring compartments and reverse-polarity battery protection.


Designed primarily for marine and commercial applications worldwide, TRUECHARGE2 Battery Chargers are unmatched for reliability. Available in three 12-volt models, they are versatile enough to be used in a wide variety of conditions and locations. Auto-ranging AC input voltage capability (90 - 265 volts AC) makes traveling abroad and handling poor-quality power a breeze. The easy-to-read display can be augmented with an optional remote panel.

 

 

 

 

Performance Features:

  12-volt models available in 20 A, 40 A and 60 A

  Microprocessor-controlled, multistage charging algorithms

  Settings for two and three-stage charging

  Settings for flooded, gel, AGM or lead-calcium batteries

  Auto-ranging universal input voltage (90-265 Vac, 47-63 Hz) is also compatible with a generator or other low-quality power sources

  Temperature-compensated charging

  Power factor corrected for efficient charging

  Battery-equalization feature

  Ability to charge ‘dead’ batteries

  Battery temperature sensor available (Part #808-0232-01)

  Optional remote display includes a maximum charger output control (Part #808-8040-00)

 

Protection Features:

  Reverse battery polarity protection

  Drip-proof design.

  Over and under-temperature protection

  DC over-voltage protection 

  Battery overcharging protection

  Ignition protection

 

20, 40 and 60 amp 12-volt Multistage Battery Chargers  

Electrical Specifications (@ 25°C unless otherwise noted  

Models

TRUECHARGE2 20 / 40 TRUECHARGE2 60

Output current (nominal)

20 A / 40 A 60 A

Output voltage (nominal, depending on settings)

Charge

14.2 - 15.5 Vdc 14.2 - 15.5 Vdc

Float

13.4 - 13.8 Vdc 13.4 - 13.8 Vdc

Equalize

16 Vdc 16 Vdc

DC output connections

Three Three
AC input voltage 1 90-265 Vac 47-63 Hz

120 Vac, 230 Vac, 240 Vac nominal
90-265 Vac 47-63 Hz

120 Vac, 230 Vac, 240 Vac nominal
Temperature compensation Three settings or optional remote battery temperature sensor
Charger efficiency > 80% > 80%
Battery type Gel, Flooded, AGM and Pb-Ca Gel, Flooded, AGM and Pb-Ca
Minimum recommended battery bank size  40 Ah for 20 A / 80 Ah for 40 A  120 Ah for 60 A

 

 

General Specifications  

Models

TRUECHARGE2 20 / 40

TRUECHARGE2 60

Operating temperature 2

0 to 65°C 0 to 65°C

Storage temperature

-40 to 80°C -40 to 80°C

Battery connection

Three positive terminals

One negative terminal

Three positive terminals

One negative terminal

Dimensions (H x W x L)

2.8 x 6.7 x 9.8” (70 × 170 × 250mm)

3.5 x 6.7 x 13.4” (90 x 170 x 340 mm)

Weight

4.8 lb (2.2 kg)

9.9 lb (4.5 kg)

Warranty

Two year

Two year

Part Numbers

804-1220 / 804-1240 804-1260

 

Accessories  

Remote panel

808-8040-00

Battery temperature sensor

808-0232-01

     

  

Regulatory Compliance   

 

CSA E60335-2-29, UL1564, and UL1236 including the Marine Supplement, drip test, and Ignition Protection ratings. CE Marked for the Low Voltage Directive
(safety) and the EMC Directive. Complies with IEC 60335-2-29 including Australian deviations. Ingress protection rating IP32 per EN/IEC 60529. Complies with
FCC Part 15B and Industry Canada ICES-003 Class B emissions limits. Complies with ABYC A-31

  

1 90 - 104 Vac ± 4 Vac output de-rated to 80% of full load current
2 For 20A and 40A charger, output current derates above 50°C. For 60 A charger, output current derates above 40°C. Highly Accelerated Life Tested (HALT) to -20°C.
Note: Specifications subject to change without notice.

 

Three-Stage Charging

Multistage charging ensures batteries receive optimum charging, but with minimal wear and tear, regulating the voltage and current delivered
to the batteries in three automatic stages:

 

  Bulk: Replaces 70-80% of the battery’s state-of-charge at the fastest possible rate.

  Absorption: Replenishes the remaining 20-30% of charge, bringing the battery to a full charge at a slow, safe rate.

  Float: Voltage is reduced and held constant in order to prevent damage and maintain batteries at a full charge.

 

Power Factor Corrected (PFC)

Less shorepower is required for charging batteries, freeing up more usable AC power for running electrical devices and appliances and reducing
the likelihood of tripping shorepower breakers.

 

 

 

© 2010 Xantrex Technology Inc. All rights reserved. Xantrex and TRUECHARGE are trademarks of Schneider Electric Services International sprl, registered in the U.S. and other countries

SÉRIE C XANTREX

Publicado em: Xantrex ,
Escrito por Terça, 05 Setembro 2017 13:25

C Series:

Charge, Diversion, or Load Controllers

 

 

 

 

Features:

  The C Series offers three models, the C35, C40, and C60, that can handle 35, 40,and 60 amps of DC current.

  Silent, pulse width modulated (PWM), high efficiency operation.

  Three-stage battery charging (bulk, absorption, and float).

  Automatic overload protection in both active and passive modes.

  PV array short circuit and reverse polarity protection.

  Durable construction.

  Backed by a two year warranty.

  Microprocessor controlled.

 

As a Solar Charge Controller:

  When used as a solar charge controller, the C40 can control 12, 24, or 48 VDC array operation and the C35 and C60 can control 12 and 24 VDC array operation.

  All units offer selectable settings for NiCad, flooded lead acid, gel, or absorbed glass mat batteries.

 

As a DC Load Controller:

  As a DC load controller, the C Series has a low voltage disconnect warning system and field adjustable set points that govern automatic low and high voltage disconnect.

  Manual reset switch for emergency low voltage operation.

 

As a Diversion Load Controller:

  The C Series automatically directs extra power to a dedicated load such as an electric water heater and ensures batteries are never over-charged.

 

Options:

  Plug-in remote temperature sensor (BTS) for increased charging precision.

  Cumulative amp-hour meter (CM) that can be installed on the face of the controller, or remotely (CM/R), up to 100 feet (30 m) away.

 

  

Electrical Specifications   C35 C40 C60

Voltage Configurations

 12 and 24 VDC  12, 24, and 48 VDC  12 and 24 VDC

Maximum PV Open Circuit Array Voltage

 55 VDC  125 VDC  55 VDC

Charging / Load Current (@ 25 °C)

 35 amps DC  40 amps DC  60 amps DC

Maximum Peak Current

 85 amps  85 amps  85 amps

Maximum Voltage Drop Through Controller

 0.30 volts  0.30 volts  0.30 volts

Typical Operating Consumption

 15 ma  15 ma  15 ma

Typical Idle Consumption

 3 ma  3 ma  3 ma
Recommended Breaker Size  45 amps  50 amps 60 amps rated at 100% continuous duty
Recommended Wire Size #8 AWG #8 AWG #6 AWG rated at 90 °C
Lead Acid Battery Settings Adjustable Adjustable Adjustable
NiCad Battery Settings Adjustable Adjustable Adjustable
Load Control Mode      
Low Voltage Reconnect Adjustable (sticker provided with unit) Adjustable (sticker provided with unit) Adjustable (sticker provided with unit)
Low Voltage Disconnect User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a one time, user selected grace period

 

 

Mechanical Specifications  

Specified Temperature Range

32 °F to 104 °F (0 °C to 40 °C)

32 °F to 104 °F (0 °C to 40 °C)

32 °F to 104 °F (0 °C to 40 °C)

Enclosure Type

Indoor, ventilated, powder coated steel
with 3/4” and 1” knockouts

Indoor, ventilated, powder coated steel
with 3/4” and 1” knockouts

Indoor, ventilated, powder coated steel
with 3/4” and 1” knockouts

Unit Weight

2.5 lb (1.2 kg) 3.0 lb (1.4 kg) 3.0 lb (1.4 kg)

Shipping

3.0 lb (1.4 kg)

3.5 lb (1.6 kg)

3.5 lb (1.6 kg)

Dimensions (H x W x D)

8.0” x 5.0” x 2.5” (20.3 cm x 12.7 cm x 6.4 cm )

10” x 5” x 2.5” (25.4 cm x 12.7 cm x 6.35 cm)

10” x 5” x 2.5” (25.4 cm x 12.7 cm x 6.35 cm)

Shipping Dimensions (H x W x D)

12.4” x 7“ x 2.5” (31.5 cm x 17.8 cm x 6.4 cm)

12.4” x 7“ x 2.5” (31.5 cm x 17.8 cm x 6.4 cm)

12.4” x 7“ x 2.5” (31.5 cm x 17.8 cm x 6.4 cm)

Mounting

Vertical wall mount - indoor only

Vertical wall mount - indoor only

Vertical wall mount - indoor only

Altitude

     

Operating

15,000’ (4,572 m) 15,000’ (4,572 m) 15,000’ (4,572 m)

Non-Operating

50,000’ (15,240 m) 50,000’ (15,240 m) 50,000’ (15,240 m)

 

Features and Options  

Regulation Method

Solid state, three-stage (bulk, absorption, and float), pulse width modulation

Field Adjustable Control Setpoints

Two user adjustable voltage setpoints for control of loads or charging sources - settings retained if battery is disconnected

Control Panel

CM, CM/R-50, or CM/R-100 - optional LCD - backlit, alphanumeric display showing battery voltage, DC amperage, cumulative amp hours, and
amp hours since last reset - remote includes 50’ (15 m) or 100’ (30.5 m) cable

Equalization Charge

User selectable manual or automatic equalization - every 30 days

Battery Temperature Sensor

BTS - optional remote battery temperature sensor for increased charging precision

     

  

Common Specifications    

Listings

UL Listed to UL 1741 - 1999 and to CSA 22.2 No. 107.1-95 Standards, CE compliant

  

 

 

 

©2001 Xantrex Technology Inc..All rights reserved.Specifications subject to change without notice.

Solar XW MPPT60 150

Publicado em: Xantrex ,
Escrito por Quinta, 10 Agosto 2017 15:19

The Xantrex XW Solar Charge Controller (XW SCC) is a photovoltaic (PV) charge controller that tracks the electrical maximum power point of a PV array to deliver the maximum available current for charging batteries. When charging, the XW SCC regulates battery voltage and output current based on the amount of energy available from the PV array and state-of-charge of the battery.

The XW SCC can be used with 12, 24, 36, 48, and 60-volt DC battery systems and is able to charge a lower nominal-voltage battery from a higher nominal-voltage array. For example, the XW SCC can charge a 12-volt battery from a 36-volt array. This provides flexibility for installers to use longer wiring runs without compromising efficiency. The XW Solar Charge Controller can be installed (in single or multi-unit configurations) with Xantrex XW Hybrid Inverter/Charger(s) or can be used in other solar energy systems where a solar charge controller is needed.

The XW SCC incorporates a dynamic Maximum Power Point Tracking (MPPT) algorithm designed to maximize energy harvest from the PV array. The MPPT constantly adjusts the operating points of the array to ensure it stays on the maximum power point. It does not stop energy harvest to sweep the array like some other competing products. This feature is beneficial all sunlight conditions, especially in areas with fast moving cloud cover and quickly changing solar conditions.

 

 

 

 

 EspecificStandard features of the Solar Charge Controller include:

  Maximum Power Point Tracking (MPPT) delivers maximum available power from PV array to battery bank

  Integrated PV ground-fault protection

  Ultra-reliable, convection-cooled design does not require a cooling fan − large, aluminum, die-cast heat-sink allows full output current up to 45°C without thermal derating

  Selectable two or three-stage charging algorithms with manual equalization to maximize system performance and improve battery life

  Configurable auxiliary output

  Two-line, 16-character liquid crystal display (LCD) and four buttons for configuration and system monitoring

  Input over-voltage and under-voltage protection, output over-current protection, and backfeed (reverse current) protection (warning and fault messages appear on LCD when unit shuts down as a protective measure)

  Over-temperature protection and power derating when output power and ambient temperature are high

  Battery Temperature Sensor (BTS) included − automatically provides temperature-compensated battery charging

  Xanbus™-enabled network communications protocol (developed by Xantrex)

  Communicates settings and activity to other Xanbus™-enabled devices, such as the XW Hybrid Inverter/Charger, the XW System Control Panel (XW SCP), XW Automatic Generator Start (XW AGS), and other XW Solar Charge Controllers.

  Five-year warranty

 

  

Electrical Specifications  

Vmpp (V) Tensão no Ponto de Máxima Potência

30,1

Maximum PV array voltage (operating)

140 Vdc

Maximum PV array open circuit voltage

150 Vdc

Array short-circuit current

60 Adc maximum

Maximum and minimum wire size in conduit

#6 AWG to #14 AWG

Total power consumption while operating

2.5 W (tare)

Charger regulation method:

Three-stage (bulk, absorption, float)

 

Two-stage (bulk, absorption)

 

 

Mechanical Specifications  

Dimensions (H × W × D)

14 ½ × 5 ¾ × 5 ½” (368 × 146 × 138 mm)

Weight (Controller only)

10.75 lb (4.8 kg)

Weight (shipping)

17.6 lb (8 kg)

Shipping dimensions (H × W × D)

19 × 9 × 9 ¾” (483 × 229 × 350 mm)

Mounting

Vertical wall mount

Standard warranty

Five years

Part number

865-1030

 

Environmental Specifications  

Enclosure type

Indoor, ventilated, sheet metal chassis with 7/8”and 1” (22.22 mm and 27.76 mm) knockouts and aluminum heat-sink

Operating temperature range (full power)

-4 to 113 °F (-20 to +45 °C)

Storage temperature

-40 to 185 °F (-40 to +85 °C)

Altitude limit (operating)

Sea level to 15,000 feet (4572 m) @ 15 °C

     

 

 

Optional Accessories  

XW System Control Panel

865-1050

XW Automatic Generator Start

865-1060

Network cables:

 

3 feet (0.9 m)

809-0935

5 feet (1.5 m)

809-0936

7 feet (2.0 m)

809-0937

10 feet (3.0 m)

809-0938

14 feet (4.3 m)

809-0939

25 feet (7.6 m)

809-0940

50 feet (15.2 m)

809-0941

75 feet (22.9 m) 809-0942
Network terminators: Male (two per pack): 809-0901
  Female (two per pack): 809-0905

 

Regulatory Approvals  

 

Certified to UL 1741 1st Edition and to CSA 107.1-01 and carries the c(CSA)us mark

 

 

 

 

Specifications subject to change without notice  - For more information on the XW Series System please visit www.xantrex.com/xw

FREEDOM SW 2000 Sine Wave Inverter/Charger

Publicado em: Xantrex ,
Escrito por Terça, 08 Agosto 2017 14:33

PURE POWER. TRUE VALUE.

The Freedom SW 2000 inverter/charger features pure sine wave output and power factor corrected multi-stage charging to meet power needs of today’s sensitive and sophisticated electronics. The Freedom SW 2000 offers premium performance and hard-to-match pricing in one package. It provides 2000 watts of continuous sine wave power to operate commonly used AC-powered electronics such as plasma television sets, microwaves, entertainment systems, computers, printers, power tools, mini refrigerator and much more. It packs a powerful 100 A charger and is available with an optional GFCI.

 

 

 

Application

  Designed for a variety of mobile applications such as commercial, emergency and recreational vehicles,
marine vessels, construction and military equipment.

 

Product Features

  Pure sine wave output to operate sensitive electronics

  Built-in transfer switch automatically transfers between inverter power and incoming AC power

  Power factor corrected multi-stage charger for fast, efficient charging

  Temperature compensated charging for all climate conditions

  Wide operating temperature range: 32°F to 122°F (0°C to 50°C)

  Ignition lockout prevents unnecessary battery drain when the alternator is not providing power*

  Adjustable low battery voltage cut-off

  Conformal coated circuit boards for humid environments

  On/off remote control panel with 25’ cable included (Part# 808-9002)

  Easy to install and easy to use

  Optional GFCI (part# 808-9003)

  Meets CSA, UL458 (with marine supplement), ABYC and FCC Part 15, Class B requirements

 

*When used with On/off remote panel

 

Protection Features

  Battery over-voltage and under-voltage protection

  Over-temperature shutdown

  Automatic overload protection

  Short-circuit protection

  Ground-fault protection on units with GFCI option

 

Also Available

  FREEDOM SW 3000 Sine Wave Inverter/Charger (Part# 815-3000) 

 

Electrical Specifications - Inverter  

Output power (continuous at 30°C)

2000 W

Surge rating (10 seconds)

4000 W

Output frequency

60 Hz ± 0.2 Hz

Output voltage

120 Vac

Output wave form

Pure sine wave

Optimal efficiency

90%

No-load power draw (inverting)

2 Adc

Input DC voltage range

11 - 15 Vdc

AC connections

Single

Low battery voltage cut-off

10.5 V, 11.8 V (selectable)

 

 

Electrical Specifications - Charger

Output current

100 A

Output voltage

12 Vdc

Output voltage range

10.0 - 15.5 Vdc

Charge control

3 stage with manual equalize

Charge temperature compensation

Battery temperature sensor (included)

Optimal Efficiency

> 85%

AC input power factor (full power)

> 0.98

Input current (for 100/150 A charging)

15.8 Aac

Input AC voltage

120 Vac

Input AC voltage range

95 - 140 Vac
Dead battery charge > 8.5 Vdc

 

    

General Specifications  
Compatible battery types Flooded / gel / AGM /
Transfer relay rating 30 A, 120 Vac
Transfer time (AC to inverter and inverter to AC) 20 ms
Optimal operating temperature range - 4°F to 122°F (- 20°C to 50°C)
Storage ambient temperature range - 4°F to 167°F (- 20°C to 75°C)
Optimal operating temperature range 0°C to 50°C
Unit dimensions (H x W x L) 7.75 x 13.5 x 15.25” (19.7 x 34.3 x 38.7 cm)
Unit weight 27.5 kg (60.5 lbs)
Warranty 2 years
Master carton quantity 1
Master carton dimensions 11.8 x 17.1 x 20.5” (30 x 43.5 x 52.2 cm)
Master carton weight 30 kg (66 lbs)
Part Number 815-2000

 

Accessories  
Freedom SW on/off remote panel Part# 808-9002 - INCLUDED
Battery Temperature Sensor Part# 808-0232-01 - INCLUDED
GFCI Option Part# 808-9003 - SOLD SEPARATELY
Drip shield Part# 808-9004 - SOLD SEPARATELY

 

 

Regulatory & Environmental Compliance  
ETL certified to CSA 107.1, UL458 with marine supplement**, FCC Class B

*When used with the Drip Shield. Drip Shield sold separately. Note: Specifications subject to change without notic
  

 

 

 

© 2010 Xantrex Technology Inc. All rights reserved. Xantrex and Smart choice for power are trademarks of Xantrex International, registered in the U.S. and other countries.

FREEDOM SW 3000 Sine Wave Inverter/Charger

Publicado em: Xantrex ,
Escrito por Terça, 08 Agosto 2017 14:00

PURE POWER. TRUE VALUE.

The Freedom SW 3000 inverter/charger is packed with features and it is one of the most advanced inverter/chargers in the market today. It features premium sine wave output with high surge capability and temperature compensated, power factor corrected, multi-stage charging to meet power needs of
demanding loads including inductive motor loads.

The Freedom SW 3000 inverter/charger provides 3000 watts of utility grade AC power to operate commonly used AC-powered electronics such as plasma television sets, microwaves, entertainment systems, computers, printers, power tools, refrigerators and much more.

 

 

 

Application

  Designed for a variety of mobile applications such as commercial, emergency and recreational vehicles,
marine vessels, construction and military equipment.

 

Product Features

  Pure sine wave output to operate sensitive electronics

  Advanced configuration options for customized applications

  Built-in transfer switch automatically transfers between inverter power and incoming AC power

  Power factor corrected multi-stage charger for fast, efficient charging

  Temperature compensated charging for all climate conditions

  Ignition lockout prevents unnecessary battery drain when the alternator is not providing power*

  Wide operating temperature range: -4°F to 140°F (-20°C to 60°C)

  Conformal coated circuit boards for humid environments

  Dual input / Dual output AC interface

  Compatible with the Xantrex Automatic Generator Start** (Part# 809-0915)

  On/off remote control panel with 25’ cable included (Part# 808-9002)

  Field upgradeable firmware

  Meets CSA, UL458 (with marine supplement), ABYC and FCC Part 15, Class B requirements

*When used with the remote panel
**Sold separately

 

Protection Features

  Battery over-voltage and under-voltage protection

  Over-temperature shutdown

  Automatic overload protection

  Short-circuit protection

  Integrated, resettable AC breakers

 

Also Available: Freedom SW 2000 Sine Wave Inverter/Charger (Part# 815-2000)

 

Electrical Specifications - Inverter  

Output power (continuous at 25°C)

3000 W

Surge rating (10 seconds)

6000 W

Output frequency

60 Hz +/- 0.2 Hz

Output voltage

120 Vac

Output wave form

Pure sine wave

Optimal efficiency

90%

No-load power draw (inverting)

3 Adc

Input DC voltage range

10 - 16 Vdc

AC connections

Split phase in / dual out, Dual in / dual out

 

 

Electrical Specifications - Charger

Output current

150 A

Output voltage

12 Vdc

Output voltage range

5 - 16 Vdc

Charge control

3 stage with manual equalize

Charge temperature compensation

Remote battery sensor (included)

Optmial Efficiency

> 85%

AC input power factor

0.95

Input current (for 150 A charging)

22 A rms nominal

Input AC voltage

120 Vac

Input AC voltage range

95 - 140 Vac
Dead battery charge > 5 Vdc

 

    

General Specifications  
Compatible battery types Flooded / gel / AGM
Transfer relay rating 2 legs at 30 A each
Transfer time (AC to inverter and inverter to AC) < 20 ms
Optimal operating temperature range - 4°F to 140°F (- 20°C to 60°C)
Storage ambient temperature range - 40°F to 185°F (- 40°C to 85°C)
Unit Dimensions (H x W x L) 7.75 x 13.5 x 15.25” (19.7 x 34.3 x 38.7 cm)
Unit weight 33.5 kg (73.7 lbs)
Warranty 2 yea
Master carton quantity 1
Master carton dimensions (H x W x L) 11.8 x 17.1 x 20.5” (30 x 43.5 x 52.2 cm)
Master carton  weight 35 kg (77 lbs)
Part Number 815-3000

 

Accessories  
Freedom SW on/off remote panel Part# 808-2009 - INCLUDED
Battery temperature sensor Part# 808-0946 - INCLUDED
Automatic Generator Start (AGS) Part# 809-0915 - SOLD SEPARATELY
System control panel (SCP) Part# 809-0910 - SOLD SEPARATELY
25’ network cable for system control panel Part# 809-0940 - SOLD SEPARATELY
75’ network cable for system control panel Part# 809-0942 - SOLD SEPARATELY
Drip shield Part# 808-9004 - SOLD SEPARATELY

 

 

Regulatory & Environmental Compliance  
ETL certified to CSA 107.1, UL458 with marine supplement**, FCC Part 15, Class B

**When used with the Drip Shield. Drip Shield sold separately.
Note: Specifications subject to change without notice

  

 

 

 

© 2009 Xantrex Technology Inc. All rights reserved. Xantrex and Smart choice for power are trademarks of Xantrex International, registered in the U.S. and other countries.

RS Sine Wave Inverter/Charger 2000 and 3000

Publicado em: Xantrex ,
Escrito por Sexta, 04 Agosto 2017 19:07

Powerful, easy-to-use sine wave inverter/chargers featuring an upgradeable design and built-in networking.

RS Inverter/Chargers are simply the most advanced and easy to use on the market. Premium sine wave output and a high surge capability will power appliances and electronic devices, including microwaves, entertainment systems, coffee makers, power tools, and lights.

A power factor corrected three-stage charger provides long battery life by recharging batteries more quickly, while using less AC power. The stress-tested, UL458 design delivers reliable power in demanding conditions. An aluminum chassis and high-temperature operation guarantee long-term
trouble-free performance. They also meet strict electromagnetic interference standards designed to minimize interference with radios and other onboard electronics.

RS Inverter/Chargers are Xanbus Enabled, so it’s easy to connect network-enabled accessories as well as share power status and diagnostic information with other devices. Xanbus makes power management less complex, while intelligently making the best use of available power resources. The inverter/chargers and accessories have built-in flash memory so their software can be upgraded to take advantage of new features and system enhancements.

 

 

 

Product Features

  2000 watt inverter/5000 watt surge rating and 3000 watt inverter/7500 watt surge rating

  Sine wave output to power sensitive appliances and electronics

  120/150A power factor corrected multi-stage charger for fast, efficient charging

  Full power inverter and charger output to 122ºF (50ºC)

  Split phase or dual in-phase inputs offers flexible use of available AC power

  Advanced diagnostics and field upgradeable software

  Meets UL458 standards and FCC Class B regulations

  Xanbus Enabled

 

Protection Features

  Battery over voltage and under voltage protection

  Over temperature protection

  Automatic overload protection

  Short circuit protection

 

 

 

Electrical Specifications – Inverter
Model RS2000 RS3000
Output power (continuous) 2000 W 3000 W

Surge rating (5 second)

5000 W (42 A)

7500 W (60 A)

Output voltage

120 VAC

120 VAC

Output frequency

60 Hz + / -0.05% (crystal controlled)

60 Hz + / -0.05% (crystal controlled)

Output waveform

Sine wave <3% THD

Sine wave <3% THD

Peak efficiency

>92%

>90%

Efficiency (full load)

>87%

>85%

No load power draw (load sense)

<14.4 W

<20 W

AC connections

Single / Dual*

Split phase in / dual out, Dual in / dual out

AC transfer capacity

30 A (single in)

2 legs at 50 A (split phase in), 2 legs at 30 A (dual in)

Transfer time

20 ms (typical)

20 ms (typical)

*See options under ‘Part Numbers’

 

 

Electrical Specifications – Charger   

Output current

120 ADC

180 ADC

Battery voltage (nominal)

12 VDC

12 VDC

Battery voltage range

10.0 – 15.5 VDC

10.0 – 15.5 VDC

Charge control

3 stage with manual equalize

3 stage with manual equalize

Charge temperature compensation

Remote battery sensor (included)

Remote battery sensor (included)

Efficiency

85% typical

85% typical

AC input power factor

0.95

0.95

Input current (maximum charge rate 150 A)

17 A RMS (120 A)

22 A RMS (150 A)

AC input voltage

120 VAC nominal

120 VAC nominal

AC input voltage range

90 – 135 VAC

90 – 135 VAC

Compatible battery types

Wet / Gel / AGM

Wet / Gel / AGM

 

 

General

Operating temperature range

-4ºF – 122ºF (-20ºC – 50ºC)

-4ºF – 122ºF (-20ºC – 50ºC)

Storage temperature range

-40ºF – 122ºF (-40ºC – 50ºC)

-40ºF – 122ºF (-40ºC – 50ºC)

Dimensions (H x W x D)

8.17 x 13.25 x 16” (208 x 336 x 406 mm)

8.17 x 13.25 x 16” (208 x 336 x 406 mm)

Weight

68.0 lbs. (30.9 kg)

75.0 lbs. (34.01kg)

Warranty

3 years

3 years

Part Numbers

Single in / Single out
Dual in / Dual out
Dual in / Dual out - 20/20 circuit breakers
Split phase in / Dual out

809-2000
809-2005
809-2006
809-3000

Accessories

System Control Panel
Automatic Generator Start
Network Connector
Network Cable 3’
Network Cable 5’
Network Cable 7’
Network Cable 10’
Network Cable 14’
Network Cable 25’
Network Cable 50’
Network Cable 75’

809-0910
809-0915
809-0903
809-0935
809-0936
809-0937
809-0938
809-0939
809-0940
809-0941
809-0942

 

    

Regulatory Approvals
CSA/NRTL certified to CSA 107.1, UL 458
FCC Class B/Industry Canada Class B

 Note: Specifications subject to change without notice

  

 

 

 

© 2005 Xantrex Technology Inc. All rights reserved. Xantrex is a registered trademark of Xantrex International. Printed in Canada

Trace Series Inverter/Charger

Publicado em: Xantrex ,
Escrito por Sexta, 04 Agosto 2017 15:12

Based on the proven technology of the Xantrex™ DR Series, the Xantrex™ Trace Series Inverter/Charger is an economical power conversion solution designed to provide dependable modified sine wave electricity to essential circuits in the home or business during a power outage. It can also be used in conjunction with a generator or any renewable energy source in an off-grid application. In addition to providing new features, the Trace Series improves on the key features that have made the DR Series the most robust and reliable inverter/ charger line for backup power and off-grid applications.

 

 

 

Features

  New digital display shows kilowatts (kW) when inverting and amps (A) when charging, plus incorporates a
robust ON/OFF membrane switch and status indicators

  New power factor corrected (PFC) charging, combined with a more sophisticated multi-stage battery
charging algorithm, reduces electricity draw and generator run-time

  Simplified controls with a snap-on cover that protects settings from being accidentally changed

  Better thermal performance allows full output power to 50°C (122°F) without de-rating

  High surge capacity starts more difficult loads and handles overload conditions reliably

  Circuit boards are conformally-coated to protect them from corrosion for longer life & improved reliability

  Durable powder coated, corrosion resistant steel chassis

 

Options

  TR-Remote On/Off Switch – includes LED status indicator (P/N: 989-1060)

  TR-Conduit Box – connects to the DC side of the inverter and accepts ¾”, 1” or 2” conduit (P/N: 989-1050)

  

 

Electrical Specifications
Part number 989-1000 989-1010 989-1005 989-1015 989-1020 989-1025 989-1030 989-1035
Model number TR1512-120-60 TR2412-120-60 TR1524-120-60 TR2424-120-60 TR3624-120-60 TR1512-230-50 TR1524-230-50 TR2424-230-50

Invert mode:

 

 

 

 

       

Waveform

Modified sine wave

Modified sine wave

Modified sine wave

Modified sine wave

Modified sine wave Modified sine wave Modified sine wave Modified sine wave

Continuous output power

1500 VA

2400 VA

1500 VA

2400 VA

3600 VA 1500 VA 1500 VA 2400 VA

AC output voltage (rms)

120 Vac

120 Vac

120 Vac

120 Vac

120 Vac 230 Vac 230 Vac 230 Vac

AC output frequency

60 Hz

60 Hz

60 Hz

60 Hz

60 Hz 50 Hz 50 Hz 50 Hz

Rated AC output current

12.5 Aac

20 Aac

12.5 Aac

20 Aac

30 Aac 6.5 Aac 6.5 Aac 10.4 Aac

Surge capability Max. Output & Duration:

 

 

 

 

       

Overload 10 sec rating

3000 VA

4800 VA

3000 VA

4800 VA

7200 VA 3000 VA 3000 VA 4800 VA

Short Circuit 10 sec rating

50±5 Apk 

80±8 Apk

50±5 Apk

80±8 Apk

120±12 Apk 26.5±2.5 Apk 26.5±2.5 Apk 42±4 Apk

Adjustable load sensing range

5 watts minimum to 240 watts maximum

10 watts minimum to 480 watts maximum
DC input current at no load - search mode  0.35 amps  0.35 amps  0.17 amps  0.17 amps  0.20 amps  0.35 amps  0.20 amps  0.20 amps
Efficiency - peak  > 90%  > 92%  > 92%  > 93%  > 94%  > 92%  > 91%  > 94%
DC input voltage range  11.0 - 15.0 Vdc  11.0 - 15.0 Vdc  22.0 - 30.0 Vdc  22.0 - 30.0 Vdc  22.0 - 30.0 Vdc  11.0 - 15.0 Vdc  22.0 - 30.0 Vdc  22.0 - 30.0 Vdc
Rated DC input current 157 amps 252 amps 76 amps 120 amps 186 amps 158 amps 77 amps 121 amps
Load power factor (allowed) 0.8 to 1.0 (leading or lagging) 0.8 to 1.0 (leading or lagging)
Series operation  Yes - Two units can be connected to produce 120/240 Vac split phase power, stacking cable included      No  No  No
Bypass / Charge mode:                 
AC input voltage range  65 - 140 Vac (wide), 95 - 140 Vac (narrow)         120 - 253 Vac (wide), 180 -253 Vac (narrow)
AC input frequency range  55 - 64 Hz (narrow-charge & pass-through),
55 - 68 Hz (wide-charge), 41 - 68 Hz (wide pass-through)     
   45 - 55 Hz (narrow-charge & pass-through),
45 - 68 Hz (wide-charge), 41 - 68 Hz (wide pass-through)
Built-In internal supplemental breakers  30 Aac bypass
20 Aac charger
30 Aac bypass
30 Aac charger 
30 Aac bypass,
20 Aac charger 
30 Aac bypass,
30 Aac charger 
30 Aac bypass
30 Aac charger 
15 Aac bypass
8 Aac charger 
15 Aac bypass,
8 Aac charger 
15 Aac bypass,
15 Aac charger 
DC charger rate (adjustable)  10 - 70 amps 14 - 100 amps  5 - 35 amps  10 - 70 amps  10 - 70 amps  10 - 70 amps  5 - 35 amps  10 - 70 amps 
AC input current at max. charge rate  11.2 Aac  15.8 Aac  10.2 Aac  19.7 Aac  19.5 Aac  5.9 amps  6.0 amps  10.4 amps 
AC input power factor  0.88  0.89  > 0.88  0.92  0.93  0.91  > 0.83  0.92 
Multi-stage charging       Yes - bulk, absorption and float, plus
user-initiated equalize (for flooded batteries only)
   Yes - bulk, absorption and float, plus
user-initiated equalize (for flooded batteries only)
Temperature compensation Battery temperature sensor included Battery temperature sensor included
Automatic transfer relay  30 amps  30 amps  30 amps  30 amps  30 amps  15 amps  15 amps  15 amps
Transfer time (typical) < 40 ms (wide), < 20 ms (narrow < 40 ms (wide), < 20 ms (narrow)

 

 

Environmental Specifications  

Dimensions (W x H x L)

8.5 x 7.25 x 21” (216 x 184 x 546 mm)

Weight

40 lbs (18 kg)

42 lbs (19 kg)

40 lbs (18 kg)

45 lbs (20 kg)

45 lbs (20 kg)

 42 lbs (19 kg)  42 lbs (19 kg)  42 lbs (19 kg)

Shipping Dimensions (W x H x L)

12.4 x 11.8 x 26.6” (315 x 300x 675 mm)   

Shipping Weight

50 lbs (22.7 kg)

52 lbs (23.6 kg)

50 lbs (22.7 kg)

55 lbs (24.9 kg)

55 lbs (24.9 kg)

 52 lbs (23.6 kg)  52 lbs (23.6 kg)  52 lbs (23.6 kg)

Operating temperature range

0 °C to +50 °C

0 °C to +50 °C

0 °C to +50 °C

0 °C to +50 °C

0 °C to +50 °C

 0 °C to +50 °C  0 °C to +50 °C  0 °C to +50 °C

Mounting

Wall-mount (with 16” mounting centers)    Wall-mount (with 16” mounting centers)

Warranty

Two years

Two years

Two years

Two years

Two years

 Two years  Two years  Two years

 

 

Regulatory Approvals  

CSA Certified to CSA 107.1, UL1741, FCC Class B and Industry Canada, CE

Specifications subject to change without notice.

  

 

 

 

 

©2009 Xantrex Technology Inc. All rights reserved. Xantrex and Smart choice for power are trademarks of Schneider Electric Services International sprl, registered in the U.S. and other countries. Printed in Canada

Freedom Marine Inverter/Chargers 1000 - 3000 watt Modified Sine Wave

Publicado em: Xantrex ,
Escrito por Sexta, 04 Agosto 2017 14:07

AC Power Inverter with High Surge Capability, 3-Stage Charger

With filtered modified sine wave output, Freedom Marine inverter/chargers run virtually anything on your boat, from office equipment to household appliances and electronics. Temperature controlled multistage charging ensures that your batteries are recharged safely and efficiently. Its integrated transfer switch allows for automatic change-over between shorepower and inverter.

For inverter/charger control and basic system monitoring, use the Freedom Basic Remote. For advanced battery monitoring and remote control, Freedom Marine inverter/chargers can be paired with optional Link instrumentation.

 

 

 

Product Features

  MSW AC power inverter with high surge capability

  Automatic 3-stage battery charger

  Temperature compensation with equalization stage provides optimal charging of deep cycle
batteries

  Built-in transfer switch automatically transfers between inverter power and incoming AC power

  Multiple battery bank charging from the built in 15 A echo~charge

  Power sharing prevents source AC input circuit breaker from tripping

  Customized settings can be programmed with the Freedom Basic Remote or Link panels

  Aluminum chassis ideal for marine environment

  Includes battery temperature sensor

  30 month warranty

 

Protection Features

  Over voltage and under voltage protection

  Over-temperature protection

  Overload protection

  Short circuit protection

  

 

Electrical Specifications – Inverter
Models 10 15 20 25 30
Output power (continuous) 1000 W 1500 W 2000 W 2500 W 3000 W

Surge power (AC amps)

25 A

37.5 A

50 A

62.5 A

75 A

Output frequency regulation

50 or 60 Hz*

50 or 60 Hz*

50 or 60 Hz*

50 or 60 Hz*

50 or 60 Hz*

Inverter voltage regulation

120 V +/-5% true RMS

120 V +/-5% true RMS

120 V +/-5% true RMS

120 V +/-5% true RMS

120 V +/-5% true RMS

Output wave form

Modified sine wave

Modified sine wave

Modified sine wave

Modified sine wave

Modified sine wave

Efficiency (full load)

85%

86%

85%

87%

86%

Peak efficiency

93%

93%

93%

93%

93%

No load current draw (idle mode)

0.12 A

0.12 A

0.12 A

0.12 A

0.12 A

AC transfer switch

30 A

30 A

30 A

30 A

30 A

* Quartz regulated 

 

Electrical Specifications – Charger   

Charge rate

50 A DC

75 A DC

100 A DC

130 A DC

140 A DC

AC input voltage range

90 − 130 VAC

90 – 130 VAC

90 − 130 VAC

90 – 130 VAC

90 – 130 VAC

Battery voltage (nominal)

12 VDC

12 VDC

12 VDC

12 VDC

12 VDC

Battery voltage range

10.0 − 15.5 VDC

10.0 − 15.5 VDC

10.0 − 15.5 VDC

10.0 − 15.5 VDC

10.0 − 15.5 VDC

Low battery cut-out

10.0 VDC

10.0 VDC

10.0 VDC

10.0 VDC

10.0 VDC

AC input (max. charge mode)

12 A AC

16 A AC

21 A AC

26 A AC

28 A AC

Default bulk charge voltage setting

14.4 VDC

14.4 VDC

14.4 VDC

14.4 VDC

14.4 VDC

Default float charge voltage setting

13.5 VDC

13.5 VDC

13.5 VDC

13.5 VDC

13.5 VDC

Equalize charge voltage (wet cell only)

16.3 VDC

16.3 VDC

16.3 VDC

16.3 VDC

16.3 VDC

Battery charge outputs

2

2

2

3

3

Charge control

3-stage

3-stage

3-stage

3-stage

3-stage

Battery type settings

Wet / Gel 1 / Gel 2 / AGM

Wet / Gel 1 / Gel 2 / AGM

Wet / Gel 1 / Gel 2 / AGM

Wet / Gel 1 / Gel 2 / AGM

Wet / Gel 1 / Gel 2 / AGM

Equalization

Yes

Yes

Yes

Yes

Yes

Temperature sensitive charging

Yes

Yes

Yes

Yes

Yes

 

 

General Specifications  

Optimal operating temperature range

32°F − 104°F (0°C − 40°C)*derated below 0°C and above 40°C

Optional remotes

Freedom Basic Remote or Link instrumentation

Dimensions (H x W x L)

7.9 x 11.5 x 13.2” (201 x 292 x 335 mm)

Weight

34 lb (15 kg)

345 lb (20 kg)

45 lb (20 kg)

50 lb (23 kg)

50 lb (23 kg)

Warranty

30 months

30 months

30 months

30 months

30 months

Part numbers

81-1011-12

81-1511-12

81-2011-12

81-2511-12

81-3011-12

Freedom Basic Remote

84-2056-01

84-2056-01

84-2056-01

84-2056-01

84-2056-01

Link 1000

84-2019-02

84-2019-02

84-2019-02

84-2019-02

84-2019-02

Link 2000

84-2000-06

 84-2000-06  84-2000-06 84-2000-06 84-2000-06

 

Note: Specifications subject to change without notice.

  

 

 

 

RV Series GS Inverter/Chargers

Publicado em: Xantrex ,
Escrito por Quinta, 03 Agosto 2017 15:20

Reliable AC Power for Recreational Vehicles

Feature-rich and easy to install, the RV Series GS produces up to 3000 watts of continuous, modified sine wave power from a 12-volt battery bank. It is ideal for powering basic appliances and power tools. Designed for use with electricity supplied from your generator or RV campground hookup, these inverter/chargers provide automatic, multistage charging, manual battery equalization and temperature sensitive charging for optimal care of your batteries. A built-in transfer switch automatically transfers between inverter power and incoming AC power.

All RV Series products have a built-in shunt, which when paired with RC/GS Remote Panel enables advanced battery monitoring and inverter/charger control. They also have the necessary built-in hardware to be connected to your generator, enabling automatic generator starting when paired with RC/GS remote panel.

 

 

 

Product Features

  2000/2500/3000 watt inverter

  100/120/140A three-stage battery charger recharges batteries quickly and accurately

  Can be installed to transfer 30 amp or 50 amp service

  Power sharing prevents source AC input circuit breaker from tripping

  Built-in shunt enables battery fuel gauge display

  Built-in automatic starting system for generators with thermostat control

  24 month warranty

 

Options

  Models with dual branch-rated circuit breakers (2x20A, or 1x20A and 1x15A)

 

Accessories

  Compatible with RC/GS remotes

  Battery Temperature Sensor available in 15, 25 and 35 foot lengths

 

 

Electrical Specifications – Inverter
Models RV2012GS RV2512GS RV3012GS
Output power AC (max. continuous) 2000 watts 2500 watts 3000 watts

Surge rating (AC amps)

44 A

48 A

52 A

Output frequency

60 Hz +/- 0.4%

60 Hz +/- 0.4%

60 Hz +/- 0.4%

Output waveform

Modified sine wave

Modified sine wave

Modified sine wave

Peak efficiency

94%

94%

94%

AC output connections

Dual

Dual

Dual

AC input connections

Dual

Dual

Dual

AC transfer switch

50 A

50 A

50 A

 

 

Electrical Specifications – Charger   

AC input voltage

120 VAC

120 VAC

120 VAC

DC input voltage range

10.2 - 15.5 VDC

10.2 - 15.5 VDC

10.2 - 15.5 VDC

Battery voltage (nominal)

12 VDC

12 VDC

12 VDC

Max charge output DC amps

100 A

120 A

140 A

Charge Control

3-Stage

3-Stage

3-Stage

Battery type settings

Wet/Gel/AGM

Wet/Gel/AGM

Wet/Gel/AGM

Equalization

Yes

Yes

Yes

Temperature sensitive charging

Yes

Yes

Yes

 

 

General Specifications  

Operating temperature range

32°F-104°F (0°C-40°C)

32°F-104°F (0°C-40°C)

32°F-104°F (0°C-40°C)

Remote Panel

RC/GS

RC/GS

RC/GS

Optional battery temperature sensor

15, 25 and 35 foot lengths

15, 25 and 35 foot lengths

15, 25 and 35 foot lengths

Recommended Class T DC Fuse

250 A

300 A

400A

Dimensions (H x W x L)

7.25x13.12x13.9” (180x333x352mm)

7.25x13.12x13.9” (180x333x352mm)

7.25x13.12x13.9” (180x333x352mm)

Weight

45 lb (20.5 kg)

50 lb (22.7 kg)

60 lb (27.2 kg)

Warranty

24 months

24 months

24 months

Part numbers

RV2012GS
RV2012-B15/20 (20/15 circuit breakers)
RV2012-B20/20 (20/20 circuit breakers)

RV2512GS

RV3012GS

Accessories (all models)

RC/GS (on/off control and setup, state of charge, LCD, AGS)
809-0946 35’ Battery Temperature Sensor

   

 

    

Regulatory Approvals
UL and CUL listed to UL 458

  

Note: Specifications subject to change without notice. Other cable lengths and accessories are available on request.

  

 

 

 

© 2005 Xantrex Technology Inc. All rights reserved. Xantrex is a registered trademark of Xantrex International. Printed in Canada

Produtos

Newsletters

Preencha os campos abaixo para receber as novidades por e-mail:

Unitron Engenharia, Indústria & Comércio Ltda.
Rua Balsa, 601 - Vila Arcádia
CEP:  02910-000 - 
São Paulo - SP
Tel: (11) 3931-4744
Skype: Unitron.engenharia

Redes Sociais

 facebook.com/unitron
   
 twitter.com/unitron
   
 youtube.com/unitron
©2024 Copyright. Unitron. Todos os Direitos Reservados.