Building on the success of the TRUECharge™2 12-volt battery chargers, Xantrex™ now offers 24-volt battery chargers designed to meet the specific needs of marine and commercial markets. Available in 10A, 20A and 30A versions, each model packs a powerful universal charger (90-240Vac, 47-63 Hz) in an ultra-compact, lightweight package.
TRUECharge2 battery chargers are highly versatile and can be mounted in multiple positions, thanks to their inherent drip-free design characteristics. TRUECharge2 delivers outstanding low electrical interference, coupled with efficient, power factor corrected, multistage charging capability. Installation is a breeze, thanks to the easy-access AC and DC wiring compartments. The easy-to-read display can be
augmented with an optional remote panel.
TRUECharge2 24-volt chargers are available with parallel stacking feature which allows you to double the output current when used with the optional REMOTE PANEL (part #808-8040-01).
Microprocessor-controlled, multistage charging algorithms
Settings for two and three-stage charging
Settings for flooded, gel, AGM or lead-calcium batteries
Auto-ranging universal input voltage (90-265 Vac, 47-63 Hz) is also compatible with a generator or other low-quality power sources
Power factor corrected, temperature-compensated charging
Battery-equalization feature
Ability to charge batteries drained to extremely low voltage
Optional Battery temperature sensor (Part #808-0232-01)
Optional Remote Panel (Part #808-8040-01)
Reverse battery polarity protection
Drip-proof design
Over and under-temperature protection
DC over-voltage protection
Battery overcharging protection
Electrical Specifications (@ 25°C unless otherwise noted) | |
Models |
TRUECHARGE2 10 / 20 / 30 |
Output current (nominal) |
10 A / 20 A / 30 A |
Output voltage (nominal, depending on battery type settings) |
|
Charge |
28.4 - 31.0 Vdc |
Float |
26.8 - 27.6 Vdc |
Equalize |
32 Vdc |
DC output connections |
Three |
AC input voltage 1 | 90-265 Vac 47-63 Hz 120 Vac, 230 Vac, 240 Vac nominal |
Temperature compensation | Three settings |
Charger efficiency | > 80% |
Battery type | Gel, Flooded, AGM and Pb-Ca |
Minimum recommended battery bank size | 40 Ah / 80 Ah / 120 Ah |
General Specifications | |
Models |
TRUECHARGE2 10 / 20 / 30 |
Operating temperature 2 |
0 to 60°C |
Storage temperature |
-40 to 80°C |
Battery connection |
Three positive terminals |
Dimensions (H x W x L) |
10 A & 20 A - 2.8 x 6.7 x 9.8” (70 x 170 x 250mm |
Weight |
10 A & 20 A - 4.8 lb (2.2 kg) |
Warranty |
Two year |
Part Numbers |
804-2410 / 804-2420 / 804-2430 |
Accessories | |
Remote panel |
808-8040-01 |
Battery temperature sensor |
808-8040-01 |
Regulatory Compliance |
CSA E60335-2-29, UL1564, and UL1236 including the Marine Supplement, drip test, and Ignition Protection ratings. CE Marked for the Low Voltage Directive |
1 90 - 104 Vac ± 4 Vac output de-rated to 80% of full load current
² For all three models, the output current may derate above 50°C.
Highly Accelerated Life Tested (HALT) to -20°C.
Note: Specifications subject to change without notice.
Multistage charging helps ensure batteries receive optimum charging, but with minimal wear and tear, regulating the voltage and current delivered
to the batteries in three automatic stages:
Bulk: Replaces 70-80% of the battery’s state-of-charge at the fastest possible rate.
Absorption: Replenishes the remaining 20-30% of charge, bringing the battery to a full charge at a slow, safe rate.
Float: Voltage is reduced and held constant in order to prevent damage and maintain batteries at a full charge.
Less shorepower is required for charging batteries, freeing up more usable AC power for running electrical devices and appliances and reducing.
Copyright © 2011 Xantrex Technology Inc. All rights reserved. Xantrex, TRUECharge and Smart choice for power are trademarks of Schneider Electric Services International sprl, registered in the United States and other countries.
XantrexTM TRUECHARGE TM2 Battery Chargers lead the industry with a small footprint and ultra-compact design. In addition to meeting global safety and regulatory standards, TRUECHARGE2 Battery Chargers feature low electrical interference and efficient, power factor corrected multistage charging. TRUECHARGE2 Battery Chargers can be mounted virtually anywhere, given their unique drip-proof design. With certified ignition protection, even a gasoline engine room is an alternative for installation*. Trouble-free installation is ensured with easy-to-access AC and DC wiring compartments and reverse-polarity battery protection.
Designed primarily for marine and commercial applications worldwide, TRUECHARGE2 Battery Chargers are unmatched for reliability. Available in three 12-volt models, they are versatile enough to be used in a wide variety of conditions and locations. Auto-ranging AC input voltage capability (90 - 265 volts AC) makes traveling abroad and handling poor-quality power a breeze. The easy-to-read display can be augmented with an optional remote panel.
12-volt models available in 20 A, 40 A and 60 A
Microprocessor-controlled, multistage charging algorithms
Settings for two and three-stage charging
Settings for flooded, gel, AGM or lead-calcium batteries
Auto-ranging universal input voltage (90-265 Vac, 47-63 Hz) is also compatible with a generator or other low-quality power sources
Temperature-compensated charging
Power factor corrected for efficient charging
Battery-equalization feature
Ability to charge ‘dead’ batteries
Battery temperature sensor available (Part #808-0232-01)
Optional remote display includes a maximum charger output control (Part #808-8040-00)
Reverse battery polarity protection
Drip-proof design.
Over and under-temperature protection
DC over-voltage protection
Battery overcharging protection
Ignition protection
Electrical Specifications (@ 25°C unless otherwise noted | ||
Models |
TRUECHARGE2 20 / 40 | TRUECHARGE2 60 |
Output current (nominal) |
20 A / 40 A | 60 A |
Output voltage (nominal, depending on settings) |
||
Charge |
14.2 - 15.5 Vdc | 14.2 - 15.5 Vdc |
Float |
13.4 - 13.8 Vdc | 13.4 - 13.8 Vdc |
Equalize |
16 Vdc | 16 Vdc |
DC output connections |
Three | Three |
AC input voltage 1 | 90-265 Vac 47-63 Hz 120 Vac, 230 Vac, 240 Vac nominal |
90-265 Vac 47-63 Hz 120 Vac, 230 Vac, 240 Vac nominal |
Temperature compensation | Three settings or optional remote battery temperature sensor | |
Charger efficiency | > 80% | > 80% |
Battery type | Gel, Flooded, AGM and Pb-Ca | Gel, Flooded, AGM and Pb-Ca |
Minimum recommended battery bank size | 40 Ah for 20 A / 80 Ah for 40 A | 120 Ah for 60 A |
General Specifications | ||
Models |
TRUECHARGE2 20 / 40 |
TRUECHARGE2 60 |
Operating temperature 2 |
0 to 65°C | 0 to 65°C |
Storage temperature |
-40 to 80°C | -40 to 80°C |
Battery connection |
Three positive terminals |
Three positive terminals |
Dimensions (H x W x L) |
2.8 x 6.7 x 9.8” (70 × 170 × 250mm) |
3.5 x 6.7 x 13.4” (90 x 170 x 340 mm) |
Weight |
4.8 lb (2.2 kg) |
9.9 lb (4.5 kg) |
Warranty |
Two year |
Two year |
Part Numbers |
804-1220 / 804-1240 | 804-1260 |
Accessories | |
Remote panel |
808-8040-00 |
Battery temperature sensor |
808-0232-01 |
Regulatory Compliance |
CSA E60335-2-29, UL1564, and UL1236 including the Marine Supplement, drip test, and Ignition Protection ratings. CE Marked for the Low Voltage Directive (safety) and the EMC Directive. Complies with IEC 60335-2-29 including Australian deviations. Ingress protection rating IP32 per EN/IEC 60529. Complies with FCC Part 15B and Industry Canada ICES-003 Class B emissions limits. Complies with ABYC A-31 |
1 90 - 104 Vac ± 4 Vac output de-rated to 80% of full load current
2 For 20A and 40A charger, output current derates above 50°C. For 60 A charger, output current derates above 40°C. Highly Accelerated Life Tested (HALT) to -20°C.
Note: Specifications subject to change without notice.
Multistage charging ensures batteries receive optimum charging, but with minimal wear and tear, regulating the voltage and current delivered
to the batteries in three automatic stages:
Bulk: Replaces 70-80% of the battery’s state-of-charge at the fastest possible rate.
Absorption: Replenishes the remaining 20-30% of charge, bringing the battery to a full charge at a slow, safe rate.
Float: Voltage is reduced and held constant in order to prevent damage and maintain batteries at a full charge.
Less shorepower is required for charging batteries, freeing up more usable AC power for running electrical devices and appliances and reducing
the likelihood of tripping shorepower breakers.
© 2010 Xantrex Technology Inc. All rights reserved. Xantrex and TRUECHARGE are trademarks of Schneider Electric Services International sprl, registered in the U.S. and other countries
Charge, Diversion, or Load Controllers
The C Series offers three models, the C35, C40, and C60, that can handle 35, 40,and 60 amps of DC current.
Silent, pulse width modulated (PWM), high efficiency operation.
Three-stage battery charging (bulk, absorption, and float).
Automatic overload protection in both active and passive modes.
PV array short circuit and reverse polarity protection.
Durable construction.
Backed by a two year warranty.
Microprocessor controlled.
When used as a solar charge controller, the C40 can control 12, 24, or 48 VDC array operation and the C35 and C60 can control 12 and 24 VDC array operation.
All units offer selectable settings for NiCad, flooded lead acid, gel, or absorbed glass mat batteries.
As a DC load controller, the C Series has a low voltage disconnect warning system and field adjustable set points that govern automatic low and high voltage disconnect.
Manual reset switch for emergency low voltage operation.
The C Series automatically directs extra power to a dedicated load such as an electric water heater and ensures batteries are never over-charged.
Plug-in remote temperature sensor (BTS) for increased charging precision.
Cumulative amp-hour meter (CM) that can be installed on the face of the controller, or remotely (CM/R), up to 100 feet (30 m) away.
Electrical Specifications | C35 | C40 | C60 |
Voltage Configurations |
12 and 24 VDC | 12, 24, and 48 VDC | 12 and 24 VDC |
Maximum PV Open Circuit Array Voltage |
55 VDC | 125 VDC | 55 VDC |
Charging / Load Current (@ 25 °C) |
35 amps DC | 40 amps DC | 60 amps DC |
Maximum Peak Current |
85 amps | 85 amps | 85 amps |
Maximum Voltage Drop Through Controller |
0.30 volts | 0.30 volts | 0.30 volts |
Typical Operating Consumption |
15 ma | 15 ma | 15 ma |
Typical Idle Consumption |
3 ma | 3 ma | 3 ma |
Recommended Breaker Size | 45 amps | 50 amps | 60 amps rated at 100% continuous duty |
Recommended Wire Size | #8 AWG | #8 AWG | #6 AWG rated at 90 °C |
Lead Acid Battery Settings | Adjustable | Adjustable | Adjustable |
NiCad Battery Settings | Adjustable | Adjustable | Adjustable |
Load Control Mode | |||
Low Voltage Reconnect | Adjustable (sticker provided with unit) | Adjustable (sticker provided with unit) | Adjustable (sticker provided with unit) |
Low Voltage Disconnect | User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a one time, user selected grace period |
Mechanical Specifications | |||
Specified Temperature Range |
32 °F to 104 °F (0 °C to 40 °C) |
32 °F to 104 °F (0 °C to 40 °C) |
32 °F to 104 °F (0 °C to 40 °C) |
Enclosure Type |
Indoor, ventilated, powder coated steel |
Indoor, ventilated, powder coated steel |
Indoor, ventilated, powder coated steel |
Unit Weight |
2.5 lb (1.2 kg) | 3.0 lb (1.4 kg) | 3.0 lb (1.4 kg) |
Shipping |
3.0 lb (1.4 kg) |
3.5 lb (1.6 kg) |
3.5 lb (1.6 kg) |
Dimensions (H x W x D) |
8.0” x 5.0” x 2.5” (20.3 cm x 12.7 cm x 6.4 cm ) |
10” x 5” x 2.5” (25.4 cm x 12.7 cm x 6.35 cm) |
10” x 5” x 2.5” (25.4 cm x 12.7 cm x 6.35 cm) |
Shipping Dimensions (H x W x D) |
12.4” x 7“ x 2.5” (31.5 cm x 17.8 cm x 6.4 cm) |
12.4” x 7“ x 2.5” (31.5 cm x 17.8 cm x 6.4 cm) |
12.4” x 7“ x 2.5” (31.5 cm x 17.8 cm x 6.4 cm) |
Mounting |
Vertical wall mount - indoor only |
Vertical wall mount - indoor only |
Vertical wall mount - indoor only |
Altitude |
|||
Operating |
15,000’ (4,572 m) | 15,000’ (4,572 m) | 15,000’ (4,572 m) |
Non-Operating |
50,000’ (15,240 m) | 50,000’ (15,240 m) | 50,000’ (15,240 m) |
Features and Options | |
Regulation Method |
Solid state, three-stage (bulk, absorption, and float), pulse width modulation |
Field Adjustable Control Setpoints |
Two user adjustable voltage setpoints for control of loads or charging sources - settings retained if battery is disconnected |
Control Panel |
CM, CM/R-50, or CM/R-100 - optional LCD - backlit, alphanumeric display showing battery voltage, DC amperage, cumulative amp hours, and amp hours since last reset - remote includes 50’ (15 m) or 100’ (30.5 m) cable |
Equalization Charge |
User selectable manual or automatic equalization - every 30 days |
Battery Temperature Sensor |
BTS - optional remote battery temperature sensor for increased charging precision |
Common Specifications | |
Listings |
UL Listed to UL 1741 - 1999 and to CSA 22.2 No. 107.1-95 Standards, CE compliant |
©2001 Xantrex Technology Inc..All rights reserved.Specifications subject to change without notice.
The Xantrex XW Solar Charge Controller (XW SCC) is a photovoltaic (PV) charge controller that tracks the electrical maximum power point of a PV array to deliver the maximum available current for charging batteries. When charging, the XW SCC regulates battery voltage and output current based on the amount of energy available from the PV array and state-of-charge of the battery.
The XW SCC can be used with 12, 24, 36, 48, and 60-volt DC battery systems and is able to charge a lower nominal-voltage battery from a higher nominal-voltage array. For example, the XW SCC can charge a 12-volt battery from a 36-volt array. This provides flexibility for installers to use longer wiring runs without compromising efficiency. The XW Solar Charge Controller can be installed (in single or multi-unit configurations) with Xantrex XW Hybrid Inverter/Charger(s) or can be used in other solar energy systems where a solar charge controller is needed.
The XW SCC incorporates a dynamic Maximum Power Point Tracking (MPPT) algorithm designed to maximize energy harvest from the PV array. The MPPT constantly adjusts the operating points of the array to ensure it stays on the maximum power point. It does not stop energy harvest to sweep the array like some other competing products. This feature is beneficial all sunlight conditions, especially in areas with fast moving cloud cover and quickly changing solar conditions.
Maximum Power Point Tracking (MPPT) delivers maximum available power from PV array to battery bank
Integrated PV ground-fault protection
Ultra-reliable, convection-cooled design does not require a cooling fan − large, aluminum, die-cast heat-sink allows full output current up to 45°C without thermal derating
Selectable two or three-stage charging algorithms with manual equalization to maximize system performance and improve battery life
Configurable auxiliary output
Two-line, 16-character liquid crystal display (LCD) and four buttons for configuration and system monitoring
Input over-voltage and under-voltage protection, output over-current protection, and backfeed (reverse current) protection (warning and fault messages appear on LCD when unit shuts down as a protective measure)
Over-temperature protection and power derating when output power and ambient temperature are high
Battery Temperature Sensor (BTS) included − automatically provides temperature-compensated battery charging
Xanbus™-enabled network communications protocol (developed by Xantrex)
Communicates settings and activity to other Xanbus™-enabled devices, such as the XW Hybrid Inverter/Charger, the XW System Control Panel (XW SCP), XW Automatic Generator Start (XW AGS), and other XW Solar Charge Controllers.
Five-year warranty
Electrical Specifications | |
Vmpp (V) Tensão no Ponto de Máxima Potência |
30,1 |
Maximum PV array voltage (operating) |
140 Vdc |
Maximum PV array open circuit voltage |
150 Vdc |
Array short-circuit current |
60 Adc maximum |
Maximum and minimum wire size in conduit |
#6 AWG to #14 AWG |
Total power consumption while operating |
2.5 W (tare) |
Charger regulation method: |
Three-stage (bulk, absorption, float) |
Two-stage (bulk, absorption) |
Mechanical Specifications | |
Dimensions (H × W × D) |
14 ½ × 5 ¾ × 5 ½” (368 × 146 × 138 mm) |
Weight (Controller only) |
10.75 lb (4.8 kg) |
Weight (shipping) |
17.6 lb (8 kg) |
Shipping dimensions (H × W × D) |
19 × 9 × 9 ¾” (483 × 229 × 350 mm) |
Mounting |
Vertical wall mount |
Standard warranty |
Five years |
Part number |
865-1030 |
Environmental Specifications | |
Enclosure type |
Indoor, ventilated, sheet metal chassis with 7/8”and 1” (22.22 mm and 27.76 mm) knockouts and aluminum heat-sink |
Operating temperature range (full power) |
-4 to 113 °F (-20 to +45 °C) |
Storage temperature |
-40 to 185 °F (-40 to +85 °C) |
Altitude limit (operating) |
Sea level to 15,000 feet (4572 m) @ 15 °C |
Optional Accessories | |
XW System Control Panel |
865-1050 |
XW Automatic Generator Start |
865-1060 |
Network cables: |
|
3 feet (0.9 m) |
809-0935 |
5 feet (1.5 m) |
809-0936 |
7 feet (2.0 m) |
809-0937 |
10 feet (3.0 m) |
809-0938 |
14 feet (4.3 m) |
809-0939 |
25 feet (7.6 m) |
809-0940 |
50 feet (15.2 m) |
809-0941 |
75 feet (22.9 m) | 809-0942 |
Network terminators: | Male (two per pack): 809-0901 |
Female (two per pack): 809-0905 |
Regulatory Approvals |
Certified to UL 1741 1st Edition and to CSA 107.1-01 and carries the c(CSA)us mark |
Specifications subject to change without notice - For more information on the XW Series System please visit www.xantrex.com/xw
The Freedom SW 2000 inverter/charger features pure sine wave output and power factor corrected multi-stage charging to meet power needs of today’s sensitive and sophisticated electronics. The Freedom SW 2000 offers premium performance and hard-to-match pricing in one package. It provides 2000 watts of continuous sine wave power to operate commonly used AC-powered electronics such as plasma television sets, microwaves, entertainment systems, computers, printers, power tools, mini refrigerator and much more. It packs a powerful 100 A charger and is available with an optional GFCI.
Designed for a variety of mobile applications such as commercial, emergency and recreational vehicles,
marine vessels, construction and military equipment.
Pure sine wave output to operate sensitive electronics
Built-in transfer switch automatically transfers between inverter power and incoming AC power
Power factor corrected multi-stage charger for fast, efficient charging
Temperature compensated charging for all climate conditions
Wide operating temperature range: 32°F to 122°F (0°C to 50°C)
Ignition lockout prevents unnecessary battery drain when the alternator is not providing power*
Adjustable low battery voltage cut-off
Conformal coated circuit boards for humid environments
On/off remote control panel with 25’ cable included (Part# 808-9002)
Easy to install and easy to use
Optional GFCI (part# 808-9003)
Meets CSA, UL458 (with marine supplement), ABYC and FCC Part 15, Class B requirements
*When used with On/off remote panel
Battery over-voltage and under-voltage protection
Over-temperature shutdown
Automatic overload protection
Short-circuit protection
Ground-fault protection on units with GFCI option
FREEDOM SW 3000 Sine Wave Inverter/Charger (Part# 815-3000)
Electrical Specifications - Inverter | |
Output power (continuous at 30°C) |
2000 W |
Surge rating (10 seconds) |
4000 W |
Output frequency |
60 Hz ± 0.2 Hz |
Output voltage |
120 Vac |
Output wave form |
Pure sine wave |
Optimal efficiency |
90% |
No-load power draw (inverting) |
2 Adc |
Input DC voltage range |
11 - 15 Vdc |
AC connections |
Single |
Low battery voltage cut-off |
10.5 V, 11.8 V (selectable) |
Electrical Specifications - Charger | |||
Output current |
100 A |
||
Output voltage |
12 Vdc |
||
Output voltage range |
10.0 - 15.5 Vdc | ||
Charge control |
3 stage with manual equalize | ||
Charge temperature compensation |
Battery temperature sensor (included) | ||
Optimal Efficiency |
> 85% | ||
AC input power factor (full power) |
> 0.98 | ||
Input current (for 100/150 A charging) |
15.8 Aac | ||
Input AC voltage |
120 Vac | ||
Input AC voltage range |
95 - 140 Vac | ||
Dead battery charge | > 8.5 Vdc |
General Specifications | |
Compatible battery types | Flooded / gel / AGM / |
Transfer relay rating | 30 A, 120 Vac |
Transfer time (AC to inverter and inverter to AC) | 20 ms |
Optimal operating temperature range | - 4°F to 122°F (- 20°C to 50°C) |
Storage ambient temperature range | - 4°F to 167°F (- 20°C to 75°C) |
Optimal operating temperature range | 0°C to 50°C |
Unit dimensions (H x W x L) | 7.75 x 13.5 x 15.25” (19.7 x 34.3 x 38.7 cm) |
Unit weight | 27.5 kg (60.5 lbs) |
Warranty | 2 years |
Master carton quantity | 1 |
Master carton dimensions | 11.8 x 17.1 x 20.5” (30 x 43.5 x 52.2 cm) |
Master carton weight | 30 kg (66 lbs) |
Part Number | 815-2000 |
Accessories | |
Freedom SW on/off remote panel | Part# 808-9002 - INCLUDED |
Battery Temperature Sensor | Part# 808-0232-01 - INCLUDED |
GFCI Option | Part# 808-9003 - SOLD SEPARATELY |
Drip shield | Part# 808-9004 - SOLD SEPARATELY |
Regulatory & Environmental Compliance | |
ETL certified to CSA 107.1, UL458 with marine supplement**, FCC Class B |
*When used with the Drip Shield. Drip Shield sold separately. Note: Specifications subject to change without notic
© 2010 Xantrex Technology Inc. All rights reserved. Xantrex and Smart choice for power are trademarks of Xantrex International, registered in the U.S. and other countries.
The Freedom SW 3000 inverter/charger is packed with features and it is one of the most advanced inverter/chargers in the market today. It features premium sine wave output with high surge capability and temperature compensated, power factor corrected, multi-stage charging to meet power needs of
demanding loads including inductive motor loads.
The Freedom SW 3000 inverter/charger provides 3000 watts of utility grade AC power to operate commonly used AC-powered electronics such as plasma television sets, microwaves, entertainment systems, computers, printers, power tools, refrigerators and much more.
Designed for a variety of mobile applications such as commercial, emergency and recreational vehicles,
marine vessels, construction and military equipment.
Pure sine wave output to operate sensitive electronics
Advanced configuration options for customized applications
Built-in transfer switch automatically transfers between inverter power and incoming AC power
Power factor corrected multi-stage charger for fast, efficient charging
Temperature compensated charging for all climate conditions
Ignition lockout prevents unnecessary battery drain when the alternator is not providing power*
Wide operating temperature range: -4°F to 140°F (-20°C to 60°C)
Conformal coated circuit boards for humid environments
Dual input / Dual output AC interface
Compatible with the Xantrex Automatic Generator Start** (Part# 809-0915)
On/off remote control panel with 25’ cable included (Part# 808-9002)
Field upgradeable firmware
Meets CSA, UL458 (with marine supplement), ABYC and FCC Part 15, Class B requirements
*When used with the remote panel
**Sold separately
Battery over-voltage and under-voltage protection
Over-temperature shutdown
Automatic overload protection
Short-circuit protection
Integrated, resettable AC breakers
Also Available: Freedom SW 2000 Sine Wave Inverter/Charger (Part# 815-2000)
Electrical Specifications - Inverter | |
Output power (continuous at 25°C) |
3000 W |
Surge rating (10 seconds) |
6000 W |
Output frequency |
60 Hz +/- 0.2 Hz |
Output voltage |
120 Vac |
Output wave form |
Pure sine wave |
Optimal efficiency |
90% |
No-load power draw (inverting) |
3 Adc |
Input DC voltage range |
10 - 16 Vdc |
AC connections |
Split phase in / dual out, Dual in / dual out |
Electrical Specifications - Charger | |||
Output current |
150 A |
||
Output voltage |
12 Vdc |
||
Output voltage range |
5 - 16 Vdc | ||
Charge control |
3 stage with manual equalize | ||
Charge temperature compensation |
Remote battery sensor (included) | ||
Optmial Efficiency |
> 85% | ||
AC input power factor |
0.95 | ||
Input current (for 150 A charging) |
22 A rms nominal | ||
Input AC voltage |
120 Vac | ||
Input AC voltage range |
95 - 140 Vac | ||
Dead battery charge | > 5 Vdc |
General Specifications | |
Compatible battery types | Flooded / gel / AGM |
Transfer relay rating | 2 legs at 30 A each |
Transfer time (AC to inverter and inverter to AC) | < 20 ms |
Optimal operating temperature range | - 4°F to 140°F (- 20°C to 60°C) |
Storage ambient temperature range | - 40°F to 185°F (- 40°C to 85°C) |
Unit Dimensions (H x W x L) | 7.75 x 13.5 x 15.25” (19.7 x 34.3 x 38.7 cm) |
Unit weight | 33.5 kg (73.7 lbs) |
Warranty | 2 yea |
Master carton quantity | 1 |
Master carton dimensions (H x W x L) | 11.8 x 17.1 x 20.5” (30 x 43.5 x 52.2 cm) |
Master carton weight | 35 kg (77 lbs) |
Part Number | 815-3000 |
Accessories | |
Freedom SW on/off remote panel | Part# 808-2009 - INCLUDED |
Battery temperature sensor | Part# 808-0946 - INCLUDED |
Automatic Generator Start (AGS) | Part# 809-0915 - SOLD SEPARATELY |
System control panel (SCP) | Part# 809-0910 - SOLD SEPARATELY |
25’ network cable for system control panel | Part# 809-0940 - SOLD SEPARATELY |
75’ network cable for system control panel | Part# 809-0942 - SOLD SEPARATELY |
Drip shield | Part# 808-9004 - SOLD SEPARATELY |
Regulatory & Environmental Compliance | |
ETL certified to CSA 107.1, UL458 with marine supplement**, FCC Part 15, Class B |
**When used with the Drip Shield. Drip Shield sold separately.
Note: Specifications subject to change without notice
© 2009 Xantrex Technology Inc. All rights reserved. Xantrex and Smart choice for power are trademarks of Xantrex International, registered in the U.S. and other countries.
RS Inverter/Chargers are simply the most advanced and easy to use on the market. Premium sine wave output and a high surge capability will power appliances and electronic devices, including microwaves, entertainment systems, coffee makers, power tools, and lights.
A power factor corrected three-stage charger provides long battery life by recharging batteries more quickly, while using less AC power. The stress-tested, UL458 design delivers reliable power in demanding conditions. An aluminum chassis and high-temperature operation guarantee long-term
trouble-free performance. They also meet strict electromagnetic interference standards designed to minimize interference with radios and other onboard electronics.
RS Inverter/Chargers are Xanbus Enabled, so it’s easy to connect network-enabled accessories as well as share power status and diagnostic information with other devices. Xanbus makes power management less complex, while intelligently making the best use of available power resources. The inverter/chargers and accessories have built-in flash memory so their software can be upgraded to take advantage of new features and system enhancements.
2000 watt inverter/5000 watt surge rating and 3000 watt inverter/7500 watt surge rating
Sine wave output to power sensitive appliances and electronics
120/150A power factor corrected multi-stage charger for fast, efficient charging
Full power inverter and charger output to 122ºF (50ºC)
Split phase or dual in-phase inputs offers flexible use of available AC power
Advanced diagnostics and field upgradeable software
Meets UL458 standards and FCC Class B regulations
Xanbus Enabled
Battery over voltage and under voltage protection
Over temperature protection
Automatic overload protection
Short circuit protection
Electrical Specifications – Inverter | ||
Model | RS2000 | RS3000 |
Output power (continuous) | 2000 W | 3000 W |
Surge rating (5 second) |
5000 W (42 A) |
7500 W (60 A) |
Output voltage |
120 VAC |
120 VAC |
Output frequency |
60 Hz + / -0.05% (crystal controlled) |
60 Hz + / -0.05% (crystal controlled) |
Output waveform |
Sine wave <3% THD |
Sine wave <3% THD |
Peak efficiency |
>92% |
>90% |
Efficiency (full load) |
>87% |
>85% |
No load power draw (load sense) |
<14.4 W |
<20 W |
AC connections |
Single / Dual* |
Split phase in / dual out, Dual in / dual out |
AC transfer capacity |
30 A (single in) |
2 legs at 50 A (split phase in), 2 legs at 30 A (dual in) |
Transfer time |
20 ms (typical) |
20 ms (typical) |
*See options under ‘Part Numbers’
Electrical Specifications – Charger | ||
Output current |
120 ADC |
180 ADC |
Battery voltage (nominal) |
12 VDC |
12 VDC |
Battery voltage range |
10.0 – 15.5 VDC |
10.0 – 15.5 VDC |
Charge control |
3 stage with manual equalize |
3 stage with manual equalize |
Charge temperature compensation |
Remote battery sensor (included) |
Remote battery sensor (included) |
Efficiency |
85% typical |
85% typical |
AC input power factor |
0.95 |
0.95 |
Input current (maximum charge rate 150 A) |
17 A RMS (120 A) |
22 A RMS (150 A) |
AC input voltage |
120 VAC nominal |
120 VAC nominal |
AC input voltage range |
90 – 135 VAC |
90 – 135 VAC |
Compatible battery types |
Wet / Gel / AGM |
Wet / Gel / AGM |
General | ||
Operating temperature range |
-4ºF – 122ºF (-20ºC – 50ºC) |
-4ºF – 122ºF (-20ºC – 50ºC) |
Storage temperature range |
-40ºF – 122ºF (-40ºC – 50ºC) |
-40ºF – 122ºF (-40ºC – 50ºC) |
Dimensions (H x W x D) |
8.17 x 13.25 x 16” (208 x 336 x 406 mm) |
8.17 x 13.25 x 16” (208 x 336 x 406 mm) |
Weight |
68.0 lbs. (30.9 kg) |
75.0 lbs. (34.01kg) |
Warranty |
3 years |
3 years |
Part Numbers |
Single in / Single out |
809-2000 |
Accessories |
System Control Panel |
809-0910 |
Regulatory Approvals |
CSA/NRTL certified to CSA 107.1, UL 458 FCC Class B/Industry Canada Class B |
Note: Specifications subject to change without notice
© 2005 Xantrex Technology Inc. All rights reserved. Xantrex is a registered trademark of Xantrex International. Printed in Canada
Based on the proven technology of the Xantrex™ DR Series, the Xantrex™ Trace Series Inverter/Charger is an economical power conversion solution designed to provide dependable modified sine wave electricity to essential circuits in the home or business during a power outage. It can also be used in conjunction with a generator or any renewable energy source in an off-grid application. In addition to providing new features, the Trace Series improves on the key features that have made the DR Series the most robust and reliable inverter/ charger line for backup power and off-grid applications.
New digital display shows kilowatts (kW) when inverting and amps (A) when charging, plus incorporates a
robust ON/OFF membrane switch and status indicators
New power factor corrected (PFC) charging, combined with a more sophisticated multi-stage battery
charging algorithm, reduces electricity draw and generator run-time
Simplified controls with a snap-on cover that protects settings from being accidentally changed
Better thermal performance allows full output power to 50°C (122°F) without de-rating
High surge capacity starts more difficult loads and handles overload conditions reliably
Circuit boards are conformally-coated to protect them from corrosion for longer life & improved reliability
Durable powder coated, corrosion resistant steel chassis
TR-Remote On/Off Switch – includes LED status indicator (P/N: 989-1060)
TR-Conduit Box – connects to the DC side of the inverter and accepts ¾”, 1” or 2” conduit (P/N: 989-1050)
Electrical Specifications | ||||||||
Part number | 989-1000 | 989-1010 | 989-1005 | 989-1015 | 989-1020 | 989-1025 | 989-1030 | 989-1035 |
Model number | TR1512-120-60 | TR2412-120-60 | TR1524-120-60 | TR2424-120-60 | TR3624-120-60 | TR1512-230-50 | TR1524-230-50 | TR2424-230-50 |
Invert mode: |
|
|
|
|
||||
Waveform |
Modified sine wave |
Modified sine wave |
Modified sine wave |
Modified sine wave |
Modified sine wave | Modified sine wave | Modified sine wave | Modified sine wave |
Continuous output power |
1500 VA |
2400 VA |
1500 VA |
2400 VA |
3600 VA | 1500 VA | 1500 VA | 2400 VA |
AC output voltage (rms) |
120 Vac |
120 Vac |
120 Vac |
120 Vac |
120 Vac | 230 Vac | 230 Vac | 230 Vac |
AC output frequency |
60 Hz |
60 Hz |
60 Hz |
60 Hz |
60 Hz | 50 Hz | 50 Hz | 50 Hz |
Rated AC output current |
12.5 Aac |
20 Aac |
12.5 Aac |
20 Aac |
30 Aac | 6.5 Aac | 6.5 Aac | 10.4 Aac |
Surge capability Max. Output & Duration: |
|
|
|
|
||||
Overload 10 sec rating |
3000 VA |
4800 VA |
3000 VA |
4800 VA |
7200 VA | 3000 VA | 3000 VA | 4800 VA |
Short Circuit 10 sec rating |
50±5 Apk |
80±8 Apk |
50±5 Apk |
80±8 Apk |
120±12 Apk | 26.5±2.5 Apk | 26.5±2.5 Apk | 42±4 Apk |
Adjustable load sensing range |
5 watts minimum to 240 watts maximum |
10 watts minimum to 480 watts maximum | ||||||
DC input current at no load - search mode | 0.35 amps | 0.35 amps | 0.17 amps | 0.17 amps | 0.20 amps | 0.35 amps | 0.20 amps | 0.20 amps |
Efficiency - peak | > 90% | > 92% | > 92% | > 93% | > 94% | > 92% | > 91% | > 94% |
DC input voltage range | 11.0 - 15.0 Vdc | 11.0 - 15.0 Vdc | 22.0 - 30.0 Vdc | 22.0 - 30.0 Vdc | 22.0 - 30.0 Vdc | 11.0 - 15.0 Vdc | 22.0 - 30.0 Vdc | 22.0 - 30.0 Vdc |
Rated DC input current | 157 amps | 252 amps | 76 amps | 120 amps | 186 amps | 158 amps | 77 amps | 121 amps |
Load power factor (allowed) | 0.8 to 1.0 (leading or lagging) | 0.8 to 1.0 (leading or lagging) | ||||||
Series operation | Yes - Two units can be connected to produce 120/240 Vac split phase power, stacking cable included | No | No | No | ||||
Bypass / Charge mode: | ||||||||
AC input voltage range | 65 - 140 Vac (wide), 95 - 140 Vac (narrow) | 120 - 253 Vac (wide), 180 -253 Vac (narrow) | ||||||
AC input frequency range | 55 - 64 Hz (narrow-charge & pass-through), 55 - 68 Hz (wide-charge), 41 - 68 Hz (wide pass-through) |
45 - 55 Hz (narrow-charge & pass-through), 45 - 68 Hz (wide-charge), 41 - 68 Hz (wide pass-through) |
||||||
Built-In internal supplemental breakers | 30 Aac bypass 20 Aac charger |
30 Aac bypass 30 Aac charger |
30 Aac bypass, 20 Aac charger |
30 Aac bypass, 30 Aac charger |
30 Aac bypass 30 Aac charger |
15 Aac bypass 8 Aac charger |
15 Aac bypass, 8 Aac charger |
15 Aac bypass, 15 Aac charger |
DC charger rate (adjustable) | 10 - 70 amps | 14 - 100 amps | 5 - 35 amps | 10 - 70 amps | 10 - 70 amps | 10 - 70 amps | 5 - 35 amps | 10 - 70 amps |
AC input current at max. charge rate | 11.2 Aac | 15.8 Aac | 10.2 Aac | 19.7 Aac | 19.5 Aac | 5.9 amps | 6.0 amps | 10.4 amps |
AC input power factor | 0.88 | 0.89 | > 0.88 | 0.92 | 0.93 | 0.91 | > 0.83 | 0.92 |
Multi-stage charging | Yes - bulk, absorption and float, plus user-initiated equalize (for flooded batteries only) |
Yes - bulk, absorption and float, plus user-initiated equalize (for flooded batteries only) |
||||||
Temperature compensation | Battery temperature sensor included | Battery temperature sensor included | ||||||
Automatic transfer relay | 30 amps | 30 amps | 30 amps | 30 amps | 30 amps | 15 amps | 15 amps | 15 amps |
Transfer time (typical) | < 40 ms (wide), < 20 ms (narrow | < 40 ms (wide), < 20 ms (narrow) |
Environmental Specifications | ||||||||
Dimensions (W x H x L) |
8.5 x 7.25 x 21” (216 x 184 x 546 mm) |
|||||||
Weight |
40 lbs (18 kg) |
42 lbs (19 kg) |
40 lbs (18 kg) |
45 lbs (20 kg) |
45 lbs (20 kg) |
42 lbs (19 kg) | 42 lbs (19 kg) | 42 lbs (19 kg) |
Shipping Dimensions (W x H x L) |
12.4 x 11.8 x 26.6” (315 x 300x 675 mm) |
|||||||
Shipping Weight |
50 lbs (22.7 kg) |
52 lbs (23.6 kg) |
50 lbs (22.7 kg) |
55 lbs (24.9 kg) |
55 lbs (24.9 kg) |
52 lbs (23.6 kg) | 52 lbs (23.6 kg) | 52 lbs (23.6 kg) |
Operating temperature range |
0 °C to +50 °C |
0 °C to +50 °C |
0 °C to +50 °C |
0 °C to +50 °C |
0 °C to +50 °C |
0 °C to +50 °C | 0 °C to +50 °C | 0 °C to +50 °C |
Mounting |
Wall-mount (with 16” mounting centers) | Wall-mount (with 16” mounting centers) | ||||||
Warranty |
Two years |
Two years |
Two years |
Two years |
Two years |
Two years | Two years | Two years |
Regulatory Approvals | |||||
CSA Certified to CSA 107.1, UL1741, FCC Class B and Industry Canada, CE |
Specifications subject to change without notice.
©2009 Xantrex Technology Inc. All rights reserved. Xantrex and Smart choice for power are trademarks of Schneider Electric Services International sprl, registered in the U.S. and other countries. Printed in Canada
With filtered modified sine wave output, Freedom Marine inverter/chargers run virtually anything on your boat, from office equipment to household appliances and electronics. Temperature controlled multistage charging ensures that your batteries are recharged safely and efficiently. Its integrated transfer switch allows for automatic change-over between shorepower and inverter.
For inverter/charger control and basic system monitoring, use the Freedom Basic Remote. For advanced battery monitoring and remote control, Freedom Marine inverter/chargers can be paired with optional Link instrumentation.
MSW AC power inverter with high surge capability
Automatic 3-stage battery charger
Temperature compensation with equalization stage provides optimal charging of deep cycle
batteries
Built-in transfer switch automatically transfers between inverter power and incoming AC power
Multiple battery bank charging from the built in 15 A echo~charge
Power sharing prevents source AC input circuit breaker from tripping
Customized settings can be programmed with the Freedom Basic Remote or Link panels
Aluminum chassis ideal for marine environment
Includes battery temperature sensor
30 month warranty
Over voltage and under voltage protection
Over-temperature protection
Overload protection
Short circuit protection
Electrical Specifications – Inverter | |||||
Models | 10 | 15 | 20 | 25 | 30 |
Output power (continuous) | 1000 W | 1500 W | 2000 W | 2500 W | 3000 W |
Surge power (AC amps) |
25 A |
37.5 A |
50 A |
62.5 A |
75 A |
Output frequency regulation |
50 or 60 Hz* |
50 or 60 Hz* |
50 or 60 Hz* |
50 or 60 Hz* |
50 or 60 Hz* |
Inverter voltage regulation |
120 V +/-5% true RMS |
120 V +/-5% true RMS |
120 V +/-5% true RMS |
120 V +/-5% true RMS |
120 V +/-5% true RMS |
Output wave form |
Modified sine wave |
Modified sine wave |
Modified sine wave |
Modified sine wave |
Modified sine wave |
Efficiency (full load) |
85% |
86% |
85% |
87% |
86% |
Peak efficiency |
93% |
93% |
93% |
93% |
93% |
No load current draw (idle mode) |
0.12 A |
0.12 A |
0.12 A |
0.12 A |
0.12 A |
AC transfer switch |
30 A |
30 A |
30 A |
30 A |
30 A |
* Quartz regulated
Electrical Specifications – Charger | |||||
Charge rate |
50 A DC |
75 A DC |
100 A DC |
130 A DC |
140 A DC |
AC input voltage range |
90 − 130 VAC |
90 – 130 VAC |
90 − 130 VAC |
90 – 130 VAC |
90 – 130 VAC |
Battery voltage (nominal) |
12 VDC |
12 VDC |
12 VDC |
12 VDC |
12 VDC |
Battery voltage range |
10.0 − 15.5 VDC |
10.0 − 15.5 VDC |
10.0 − 15.5 VDC |
10.0 − 15.5 VDC |
10.0 − 15.5 VDC |
Low battery cut-out |
10.0 VDC |
10.0 VDC |
10.0 VDC |
10.0 VDC |
10.0 VDC |
AC input (max. charge mode) |
12 A AC |
16 A AC |
21 A AC |
26 A AC |
28 A AC |
Default bulk charge voltage setting |
14.4 VDC |
14.4 VDC |
14.4 VDC |
14.4 VDC |
14.4 VDC |
Default float charge voltage setting |
13.5 VDC |
13.5 VDC |
13.5 VDC |
13.5 VDC |
13.5 VDC |
Equalize charge voltage (wet cell only) |
16.3 VDC |
16.3 VDC |
16.3 VDC |
16.3 VDC |
16.3 VDC |
Battery charge outputs |
2 |
2 |
2 |
3 |
3 |
Charge control |
3-stage |
3-stage |
3-stage |
3-stage |
3-stage |
Battery type settings |
Wet / Gel 1 / Gel 2 / AGM |
Wet / Gel 1 / Gel 2 / AGM |
Wet / Gel 1 / Gel 2 / AGM |
Wet / Gel 1 / Gel 2 / AGM |
Wet / Gel 1 / Gel 2 / AGM |
Equalization |
Yes |
Yes |
Yes |
Yes |
Yes |
Temperature sensitive charging |
Yes |
Yes |
Yes |
Yes |
Yes |
General Specifications | |||||
Optimal operating temperature range |
32°F − 104°F (0°C − 40°C)*derated below 0°C and above 40°C |
||||
Optional remotes |
Freedom Basic Remote or Link instrumentation |
||||
Dimensions (H x W x L) |
7.9 x 11.5 x 13.2” (201 x 292 x 335 mm) |
||||
Weight |
34 lb (15 kg) |
345 lb (20 kg) |
45 lb (20 kg) |
50 lb (23 kg) |
50 lb (23 kg) |
Warranty |
30 months |
30 months |
30 months |
30 months |
30 months |
Part numbers |
81-1011-12 |
81-1511-12 |
81-2011-12 |
81-2511-12 |
81-3011-12 |
Freedom Basic Remote |
84-2056-01 |
84-2056-01 |
84-2056-01 |
84-2056-01 |
84-2056-01 |
Link 1000 |
84-2019-02 |
84-2019-02 |
84-2019-02 |
84-2019-02 |
84-2019-02 |
Link 2000 |
84-2000-06 |
84-2000-06 | 84-2000-06 | 84-2000-06 | 84-2000-06 |
Note: Specifications subject to change without notice.
Feature-rich and easy to install, the RV Series GS produces up to 3000 watts of continuous, modified sine wave power from a 12-volt battery bank. It is ideal for powering basic appliances and power tools. Designed for use with electricity supplied from your generator or RV campground hookup, these inverter/chargers provide automatic, multistage charging, manual battery equalization and temperature sensitive charging for optimal care of your batteries. A built-in transfer switch automatically transfers between inverter power and incoming AC power.
All RV Series products have a built-in shunt, which when paired with RC/GS Remote Panel enables advanced battery monitoring and inverter/charger control. They also have the necessary built-in hardware to be connected to your generator, enabling automatic generator starting when paired with RC/GS remote panel.
2000/2500/3000 watt inverter
100/120/140A three-stage battery charger recharges batteries quickly and accurately
Can be installed to transfer 30 amp or 50 amp service
Power sharing prevents source AC input circuit breaker from tripping
Built-in shunt enables battery fuel gauge display
Built-in automatic starting system for generators with thermostat control
24 month warranty
Models with dual branch-rated circuit breakers (2x20A, or 1x20A and 1x15A)
Compatible with RC/GS remotes
Battery Temperature Sensor available in 15, 25 and 35 foot lengths
Electrical Specifications – Inverter | |||
Models | RV2012GS | RV2512GS | RV3012GS |
Output power AC (max. continuous) | 2000 watts | 2500 watts | 3000 watts |
Surge rating (AC amps) |
44 A |
48 A |
52 A |
Output frequency |
60 Hz +/- 0.4% |
60 Hz +/- 0.4% |
60 Hz +/- 0.4% |
Output waveform |
Modified sine wave |
Modified sine wave |
Modified sine wave |
Peak efficiency |
94% |
94% |
94% |
AC output connections |
Dual |
Dual |
Dual |
AC input connections |
Dual |
Dual |
Dual |
AC transfer switch |
50 A |
50 A |
50 A |
Electrical Specifications – Charger | |||
AC input voltage |
120 VAC |
120 VAC |
120 VAC |
DC input voltage range |
10.2 - 15.5 VDC |
10.2 - 15.5 VDC |
10.2 - 15.5 VDC |
Battery voltage (nominal) |
12 VDC |
12 VDC |
12 VDC |
Max charge output DC amps |
100 A |
120 A |
140 A |
Charge Control |
3-Stage |
3-Stage |
3-Stage |
Battery type settings |
Wet/Gel/AGM |
Wet/Gel/AGM |
Wet/Gel/AGM |
Equalization |
Yes |
Yes |
Yes |
Temperature sensitive charging |
Yes |
Yes |
Yes |
General Specifications | |||
Operating temperature range |
32°F-104°F (0°C-40°C) |
32°F-104°F (0°C-40°C) |
32°F-104°F (0°C-40°C) |
Remote Panel |
RC/GS |
RC/GS |
RC/GS |
Optional battery temperature sensor |
15, 25 and 35 foot lengths |
15, 25 and 35 foot lengths |
15, 25 and 35 foot lengths |
Recommended Class T DC Fuse |
250 A |
300 A |
400A |
Dimensions (H x W x L) |
7.25x13.12x13.9” (180x333x352mm) |
7.25x13.12x13.9” (180x333x352mm) |
7.25x13.12x13.9” (180x333x352mm) |
Weight |
45 lb (20.5 kg) |
50 lb (22.7 kg) |
60 lb (27.2 kg) |
Warranty |
24 months |
24 months |
24 months |
Part numbers |
RV2012GS |
RV2512GS |
RV3012GS |
Accessories (all models) |
RC/GS (on/off control and setup, state of charge, LCD, AGS) |
Regulatory Approvals |
UL and CUL listed to UL 458 |
Note: Specifications subject to change without notice. Other cable lengths and accessories are available on request.
© 2005 Xantrex Technology Inc. All rights reserved. Xantrex is a registered trademark of Xantrex International. Printed in Canada
Unitron Engenharia, Indústria & Comércio Ltda.
Rua Balsa, 601 - Vila Arcádia
CEP: 02910-000 - São Paulo - SP
Tel: (11) 3931-4744
Skype: Unitron.engenharia